SHELLY FLOOD INTEGRATION WITH MQTT PROTOCOL WITHIN THE ILEVIA SYSTEM
INTRODUCTION
This guide will explane how to set the shelly flood device with MQTT.
This device is used to record temperature of floods and allert in case it has been set as flood detector.
This device need a 3V CR123A battery for the power supply.
Una volta connessi all’interno del suo hotspot si andrà a digitare l’IP predefinito del dispositivo che è (192.168.33.1) nella barra di ricerca del tuo browser.
Adesso andremo ad abilitare la modalità wifi nel dispositivo shelly per far si che si connetta al tuo wifi, quindi recati sulla sezione “internet security” poi su “wifi client” e infine clicca sulla casella “connect the shelly device to an existing wifi network”.
Per impostare l’MQTT nel dispositivo recarsi nella sezione Internet security, dopo di che “advanced developer settings” e cliccare sulla casella “enable action execution via MQTT”.
Put your X1 server IP address into the text field called server.
Set the Quality of Service (QoS) to 2, then click save.
1. Create a new Eve automation software project,
2. Create a new MQTT protocol as explaned in this guide.
3. Take two info component from the basic section on the left.
4. Create a new group and put those info component inside it.
Set up the other info component, this component will display the flood temperature.
Put the topic Through the event topic.
Set the mesurement unit in “temperature decimal C°” as shown in the picture below.
By clicking this link you will be able to consult the topic configuration.
Step 9:
To set the shelly flood in flood controller mode:
- Add another info component to the project as shown in the pitcture below.
- Put the right topic inside to dispay the payload.
By clicking this link you will be able to consult the topic configuration.
Debug to check the information with MQTT fx.
Follow this guide if you haven’t installed this debug software.
Subscribe to the topic of the device.
If the topics has been correctly set you should able to see the topics working inside the debug software.
This is how the final project looks like inside Eve automation app.
You should be able to see all the information the device’s sending.
1- Make sure to have the last version available for EVE manager and Eve X1 server firmware.
2- Make sure the shelly plug is connected in your network.
3- If you can’t connect to the broker check if the X1 server has been wired correctly.
Scopri molto altro riguardo alla nostra soluzione dedicata a shelly.
FAQ:
Why doesn't my shelly flood connecting to my local network?
check if the shelly plug has been turned on correctly or if the battery has been correctly mounted.