{"id":10180,"date":"2020-06-17T17:42:41","date_gmt":"2020-06-17T15:42:41","guid":{"rendered":"http:\/\/support.ilevia.com\/?p=10180"},"modified":"2024-11-08T11:53:28","modified_gmt":"2024-11-08T10:53:28","slug":"modbus-gateway","status":"publish","type":"post","link":"https:\/\/support.ilevia.com\/it\/configuration-software-en\/modbus-gateway\/","title":{"rendered":"Modbus-gateway"},"content":{"rendered":"[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;section&#8221; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;0px|||||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row admin_label=&#8221;row&#8221; _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Text&#8221; _builder_version=&#8221;4.17.3&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; use_border_color=&#8221;off&#8221; border_color=&#8221;#ffffff&#8221; border_style=&#8221;solid&#8221; global_colors_info=&#8221;{}&#8221;]\n<h1 style=\"text-align: center;\">MODBUS-RTU &amp;\u00a0MODBUS-TCP Parametri dei Gateway<\/h1>\n[\/et_pb_text][et_pb_divider _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;1px|auto||auto|false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;]\n<h2 style=\"text-align: center;\"><strong>MODBUS RTU\/ASCII<\/strong><\/h2>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,2_3&#8243; admin_label=&#8221;Row&#8221; _builder_version=&#8221;4.17.3&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_margin=&#8221;10px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_proprieta_gateway.png&#8221; alt=&#8221;Gateway Modbus RTU all&#8217;interno del software di configurazione della domotica EVE Manager&#8221; title_text=&#8221;Modbus_gateway_proprieta_gateway&#8221; show_in_lightbox=&#8221;on&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; admin_label=&#8221;Image&#8221; _builder_version=&#8221;4.16&#8243; box_shadow_style=&#8221;preset2&#8243; use_border_color=&#8221;off&#8221; border_color=&#8221;#ffffff&#8221; border_style=&#8221;solid&#8221; animation=&#8221;off&#8221; sticky=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text admin_label=&#8221;Text&#8221; _builder_version=&#8221;4.17.3&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; custom_margin=&#8221;-23px|||||&#8221; use_border_color=&#8221;off&#8221; border_color=&#8221;#ffffff&#8221; border_style=&#8221;solid&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote>\n<h3>PROPRIET\u00c0 DEL GATEWAY<\/h3>\n<\/blockquote>\n<p style=\"text-align: justify;\"><strong>Seleziona dispositivo<\/strong>: L&#8217;opzione <strong>porta A<\/strong> sul gateway all&#8217;interno delle configurazioni del gateway indica la porta di sinistra presente nel server X1 fisico, la <strong>porta B<\/strong> quella a destra;<\/p>\n[\/et_pb_text][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2021\/01\/modbus_server_x1_porte.png&#8221; alt=&#8221;Porte dedicate al cablaggio Modbus RS485 nel server per il controllo della domotica EVE Manager Pro&#8221; title_text=&#8221;modbus_server_x1_porte&#8221; show_in_lightbox=&#8221;on&#8221; _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-19px|||||&#8221; global_colors_info=&#8221;{}&#8221;]\n<ul>\n<li><strong>Baud rate<\/strong>: Imposta il <em>Baudrate<\/em> come specificato nella documentazione del dispositivo;<\/li>\n<li><strong>Bits<\/strong>: Imposta i <em>Bit<\/em> rispettivamente a come \u00e8 indicato nella documentazione del dispositivo;<\/li>\n<li><strong>Parity<\/strong>: Imposta la <em>Parit\u00e0<\/em> rispettivamente a come \u00e8 stato indicato nella documentazione del dispositivo;<\/li>\n<li><strong>Stop bit<\/strong>: Imposta il <em>bit di stop<\/em> dipendentemente da come \u00e8 indicato all&#8217;interno della documentazione del dispositivo;<\/li>\n<li><strong>Connection timeout<\/strong>: Il connection timeout avviene quando il server ci mette pi\u00f9 tempo a rispondere a un dispositivo di quello impostato.<\/li>\n<li><strong>Read interval<\/strong>:\u00a0L&#8217;intervallo di tempo che ce tra una lettura e l&#8217;altra;<\/li>\n<li><strong>Receive timeout<\/strong>: Se i dati non sono stati ricevuti nell&#8217;asso di tempo indicato in millisecondi il server generer\u00e0 un errore;<\/li>\n<li><strong>Connection CRC error timeout<\/strong>:\u00a0Nel caso ci siano degli errori di comunicazione prima di riprovare, il server aspetter\u00e0 il tempo impostato in millisecondi;<\/li>\n<li><strong>Wait interval if frame failed<\/strong>:\u00a0 Tempo d&#8217;attesa in millisecondi in caso di frame fallito;<\/li>\n<li><strong>Wait interval if frame success<\/strong>: Tempo di attesa in millisecondi nel caso di frame corretto;<\/li>\n<li><strong>Bytes order<\/strong>: Definisce l&#8217;ordine di trasmissione dei singoli byte di una informazione tramite una linea seriale;<\/li>\n<li><strong>Ascii transform<\/strong>: Questa spunta permette all&#8217;utente di programmare dispostivi tramite metodo Modbus Ascii;<\/li>\n<li><strong>Remove echo from serial<\/strong>: Se l&#8217;hardware usato elimina l&#8217;echo automaticamente, lascia questa spunta non selezionata;<\/li>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;||20px||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; global_colors_info=&#8221;{}&#8221;]\n<h2 style=\"text-align: center;\"><strong>MODBUS TCP<\/strong><\/h2>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,2_3&#8243; admin_label=&#8221;Row&#8221; _builder_version=&#8221;4.16&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_margin=&#8221;20px||||false|false&#8221; custom_padding=&#8221;0px|||||&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_proprieta_gateway-tcp.png&#8221; alt=&#8221;Come impostare il protocollo Modbus TCP all&#8217;interno del software di configurazione della domotica EVE Mananger&#8221; title_text=&#8221;Modbus_gateway_proprieta_gateway-tcp&#8221; show_in_lightbox=&#8221;on&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; admin_label=&#8221;Image&#8221; _builder_version=&#8221;4.16&#8243; box_shadow_style=&#8221;preset2&#8243; use_border_color=&#8221;off&#8221; border_color=&#8221;#ffffff&#8221; border_style=&#8221;solid&#8221; animation=&#8221;off&#8221; sticky=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; custom_margin=&#8221;-21px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote>\n<h3>POPRIET\u00c0 DEL GATEWAY<\/h3>\n<\/blockquote>\n<ul>\n<li><strong>Indirizzo<\/strong>(campo di testo): Qui sar\u00e0 necessario inserire l&#8217;indirizzo IP dell&#8217;interfaccia di rete Modbus.<\/li>\n<li><strong>Porta<\/strong>(campo di testo)<strong>:\u00a0<\/strong>Qui sar\u00e0 necessario aggiungere la porta a cui il server X1 si baser\u00e0 per la connessione all&#8217;interfaccia Modbus;<\/li>\n<li><strong>Timeout connessione<\/strong>: Il connection timeout avviene quando il server ci mette pi\u00f9 tempo a rispondere a un dispositivo di quello impostato;<\/li>\n<li><strong>Intervallo di lettura<\/strong>(campo di testo):\u00a0 L&#8217;intervallo di tempo che ce tra una lettura e l&#8217;altra;<\/p>\n<li><strong>Timerout di ricezione<\/strong>(campo di testo): Se i dati non sono stati ricevuti nell&#8217;asso di tempo indicato in millisecondi il server generer\u00e0 un errore;<\/li>\n<li><strong>Errore timeout connessione CRC<\/strong>:\u00a0 nel caso ci siano degli errori di comunicazione prima di riprovare, il server aspetter\u00e0 il tempo impostato in millisecondi;<\/li>\n<li><strong>Attendi intervallo di tempo se il frame fallisce<\/strong>:\u00a0 tempo d&#8217;attesa in millisecondi in caso di frame fallito;<\/li>\n<li><strong>Attendi intervallo di tempo se il frame<\/strong>: tempo di attesa in millisecondi nel caso di frame corretto;<\/li>\n<li><strong>Ordine dei Bytes<\/strong>: Definisce l&#8217;ordine di trasmissione dei singoli byte di una informazione tramite una linea seriale;<\/li>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;20px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align:center\">CONFIGURAZIONI  MODBUS TIPICHE DI UN COMPONENTE<\/h3>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,2_3&#8243; _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;10px|auto|0px|auto|false|false&#8221; custom_padding=&#8221;||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_configurazioni-componente.png&#8221; alt=&#8221;Componente con gateway Modbus all&#8217;interno del software per la configurazione della domotica EVE Manager&#8221; title_text=&#8221;Modbus_gateway_configurazioni-componente&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;-21px|||||&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote><p><b>Configurazioni parametri READ \/ WRITE<\/b><\/p><\/blockquote>\n<ul>\n<li><strong>ID Unit\u00e0<\/strong>: Scegli l&#8217;<em>ID unit\u00e0<\/em> corretto del dispositivo. Questo parametro \u00e8 indicato all&#8217;interno del documento del dispositivo contenente le configurazioni modbus, in alcuni casi \u00e8 necessario impostarlo manualmente;<\/li>\n<li><strong>ID Funzione<\/strong>: Scegli il corretto <em>ID Funzione<\/em> del registro, questo parametro \u00e8 indicato all&#8217;interno della documentazione del dispositivo.<\/li>\n<li><strong>Start register<\/strong>: Inserisci il registro di partenza dalla documentazione Modbus del dispositivo, <\/li>\n<li><strong>Conteggio Registri o Bobine<\/strong>: Questo parametro permette di contare precisamente le bobine o registri da un registro di partenza;<\/li>\n<li><strong>Start Bit<\/strong>: Inserisci il bit di partenza, alcuni registri contengono molteplici bit i quali interscambiano con il dispositivo Master infomrazioni divere in base al bit selezionato;<\/li>\n<li><strong>Count Bits<\/strong>: Quanti bit devono essere contati all&#8217;interno del singolo registro;<\/li>\n<\/ul>\n<blockquote><p><b>Data trasform<\/b><\/p><\/blockquote>\n<ul>\n<li><strong>Tipo<\/strong>: Seleziona il <em>fromato del dato<\/em> corretto;<\/li>\n<li><strong>Min<\/strong>: Inserisci la cifra <em>Minima<\/em> la quale potr\u00e0 essere raggiunta dal valore derivante dal modbus;<\/li>\n<li><strong>Max<\/strong>: Inserisci la cifra <em>Massima<\/em> la quale potr\u00e0 essere raggiunta dal valore derivante dal modbus;<\/li>\n<li><strong>Moltiplicatore<\/strong>: Inserisci la cifrala quale sar\u00e0 moltiplicata al valore derivante dal modbus;<\/li>\n<li><strong>Decimali<\/strong>: Parametro che andr\u00e0 ad limitare la visualizzazione di decimali derivanti dal registro modbus;<\/li>\n<li><strong>Digits format<\/strong>: Inserisci quante cifre vengono visualizzate dal valore derivante dal modbus.<\/li>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_3,2_3&#8243; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;1_3&#8243; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2023\/11\/Modbus_gateway_Read-Coils-configurazioni.png&#8221; alt=&#8221;Configurazione componente info con funzione Read coils all&#8217;interno del software di configurazione di Ilevia EVE Manager.&#8221; title_text=&#8221;Modbus_gateway_Read-Coils-configurazioni&#8221; show_in_lightbox=&#8221;on&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;20px||||false|false&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][et_pb_column type=&#8221;2_3&#8243; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote>\n<p><strong>Configurazione lettura dei Coil (0x01 Read coil)<\/strong><\/p>\n<\/blockquote>\n<p>Nel caso specifico di una configurazione per la lettura di <b>Coil<\/b> con la funzione <b>(1) Read coils<\/b>, sar\u00e0 necessario impostare parametri specificiall&#8217;interno delle configurazioni del componente.<\/p>\n<p>Il componente configurato con il gateway Modbus presenta due parametri che nel caso della lettura dei <b>Coils<\/b> necessitano di una configurazione specifica per la lettura corretta dei dati inviati dal dispositivo Slave, le impostazioni sono le seguenti:<\/p>\n<\/p>\n<ul>\n<li>\n<p style=\"text-align:justify\"><strong>Bit di partenza:<\/strong> Il bit di partenza deve essere impostato con 0 nel momento in cui si vuole leggere il bit 0. Diverso invece se il bit da leggere interessato \u00e8 diverso da 0, in quel caso baster\u00e0 specificare il numero corretto del bit di partenza.<\/p>\n<\/li>\n<li>\n<p style=\"text-align:justify\"><strong>Bit da contare:<\/strong> L&#8217;impostazione Count Bit specifica il numero di bit che il server conta del registro specificato.<\/p>\n<\/li>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221;][et_pb_column _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;]\n<blockquote>\n<h3>Modbus RTU\/over TCP and TCP 2<\/h3>\n<\/blockquote>\n<p>Nelle versioni pi\u00f9 recenti del server Ilevia\u00e8 possibile scegliere la seconda versione del <b>protocollo Modbus<\/b>. La differenza sostanziale del tra i due protocolli \u00e8 che, la versione due del protocollo, viene gestita completamente dal <a href=\"\/it\/maintenance-diagnostics\/logic-module-update\/\" target=\"_blank\" rel=\"noopener\">modbulo logiche<\/a> del server.<\/p>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.17.3&#8243; custom_margin=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_divider color=&#8221;#000000&#8243; _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_divider][et_pb_text _builder_version=&#8221;4.17.3&#8243; custom_margin=&#8221;0px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align:center\">ESEMPI CABLAGGIO DEI SERVER ILEVIA CON PROTOCOLLO MODBUS<\/h3>\n<p><\/br><\/p>\n<p>Nelle immagini sottostanti potrai vedere le molteplici possibilit\u00e0 di connesione che puoi avere usando un server X1, Raspberry Pi oppure una macchina viruale come Modbus Master con EVE Manager.<\/p>\n[\/et_pb_text][et_pb_text _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align: center;\">SERVER X1<\/h3>\n[\/et_pb_text][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_wiring-example1.png&#8221; alt=&#8221;Come funziona il server domotico EVE X1 all&#8217;interno di Modbus&#8221; title_text=&#8221;Modbus_gateway_wiring-example1&#8243; show_in_lightbox=&#8221;on&#8221; show_bottom_space=&#8221;off&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.16&#8243; max_width=&#8221;70%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;30px||50px||false|false&#8221; border_radii=&#8221;on|10px|10px|10px|10px&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align: center;\"><strong>SERVER RASPBERRY PI<\/strong><\/h3>\n[\/et_pb_text][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_wiring-example2.png&#8221; alt=&#8221;Come funziona il raspberry pi all&#8217;interno di Modbus&#8221; title_text=&#8221;Modbus_gateway_wiring-example2&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.16&#8243; max_width=&#8221;70%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;30px||50px||false|false&#8221; border_radii=&#8221;on|10px|10px|10px|10px&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||0px||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align: center;\">SERVER MACCHINA VIRTUALE<\/strong><\/h3>\n[\/et_pb_text][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2022\/03\/Modbus_gateway_wiring-example3.png&#8221; alt=&#8221;Come funziona la macchina virtuale all&#8217;interno di Modbus&#8221; title_text=&#8221;Modbus_gateway_wiring-example3&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.16&#8243; max_width=&#8221;70%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;30px||50px||false|false&#8221; border_radii=&#8221;on|10px|10px|10px|10px&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][et_pb_text _builder_version=&#8221;4.16&#8243; text_font=&#8221;||||||||&#8221; custom_margin=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<p><strong>Questa \u00e8 una rappresentazione su come connettiamo un dispositivo 12V al server X1:<\/strong><\/p>\n[\/et_pb_text][et_pb_image src=&#8221;https:\/\/support.ilevia.com\/wp-content\/uploads\/2019\/01\/MODBUS.png&#8221; alt=&#8221;Come si collega un dispositivo modbus al server domotico EVE X1&#8243; title_text=&#8221;Dispositivo Modbus con server X1&#8243; show_in_lightbox=&#8221;on&#8221; align=&#8221;center&#8221; align_tablet=&#8221;center&#8221; align_phone=&#8221;&#8221; align_last_edited=&#8221;on|desktop&#8221; _builder_version=&#8221;4.16&#8243; max_width=&#8221;45%&#8221; module_alignment=&#8221;center&#8221; custom_margin=&#8221;20px|||313px|false|false&#8221; border_radii=&#8221;on|10px|10px|10px|10px&#8221; box_shadow_style=&#8221;preset2&#8243; global_colors_info=&#8221;{}&#8221;][\/et_pb_image][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_divider _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_divider][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]\n<h3 style=\"text-align: center;\">ESEMPIO CONFIGURAZIONI MODBUS<\/h3>\n<blockquote>\n<p><strong>Esempi configurazione dispositivi con protocollo modbus RTU:<\/strong><\/p>\n<\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; _builder_version=&#8221;4.17.3&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||30px||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<p>Qui potrai scaricare e consultare la conifgurazione Modbus del dispsoitivo <strong>contatore di energia SENECA (trifase) S534-80<\/strong>.<\/p>\n<p><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2021\/10\/SENECAmodbusRTU_it.zip\"><strong>Scarica il progetto qui!<\/strong><\/a><\/p>\n[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.20.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote><p><strong>Esempio configurazione dispositivo Finder energy meter<\/strong> con protocollo modbus RTU<\/p><\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.20.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||30px||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<p>Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo <b>Finder 7M24 &#8211; 7M38<\/b>.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2023\/07\/Finder-7M24-7M38-confs-it.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.20.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote><p><strong>Esempio configurazione dispositivo <strong>Dignitan relay board<\/strong> con protocollo modbus RTU<\/p><\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||30px||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo <b>Dingtian<\/b> sheda rel\u00e8.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2024\/10\/Dingitan-relay-board-confs.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.20.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote><p><strong>Esempio configurazione dispositivo <strong>Carlo Gavazzi misuratore di energia EM340<\/strong> con protocollo modbus RTU<\/p><\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.20.4&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo <b>Carlo Gavazzi E3M40<\/b>.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2023\/07\/Carlo-Gavazzi-EM340_Modbus-conf-it.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote><p><strong>Esempio configurazione dispositivo <strong>Inverter Fronius GEN24<\/strong> con protocollo modbus RTU<\/p><\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.0&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<p>Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo <b> Inverter Fronius GEN24<\/b>.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2024\/10\/Fronius-GEN24_progetto-configurazione.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.23.1&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote>\n<p><strong>Esempio configurazione dispositivo Misuratore di energia IME CE2DF3DTCL1 con protocollo modbus RTU<\/strong><\/p>\n<\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<p>Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo Misuratore di energia <b>IME CE2DF3DTCL1<\/b>.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2023\/11\/IME-CE2DF3DTCL1-configurazione-modbus.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][et_pb_text disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<blockquote>\n<p><strong>Esempio configurazione dispositivo per il controllo di luci RGB ASTRALPOOL Lumiplus con protocollo modbus RTU<\/strong><\/p>\n<\/blockquote>\n[\/et_pb_text][et_pb_testimonial portrait_url=&#8221;data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iNTAwIiBoZWlnaHQ9IjUwMCIgdmlld0JveD0iMCAwIDUwMCA1MDAiIHhtbG5zPSJodHRwOi8vd3d3LnczLm9yZy8yMDAwL3N2ZyI+CiAgICA8ZyBmaWxsPSJub25lIiBmaWxsLXJ1bGU9ImV2ZW5vZGQiPgogICAgICAgIDxwYXRoIGZpbGw9IiNFQkVCRUIiIGQ9Ik0wIDBoNTAwdjUwMEgweiIvPgogICAgICAgIDxyZWN0IGZpbGwtb3BhY2l0eT0iLjEiIGZpbGw9IiMwMDAiIHg9IjY4IiB5PSIzMDUiIHdpZHRoPSIzNjQiIGhlaWdodD0iNTY4IiByeD0iMTgyIi8+CiAgICAgICAgPGNpcmNsZSBmaWxsLW9wYWNpdHk9Ii4xIiBmaWxsPSIjMDAwIiBjeD0iMjQ5IiBjeT0iMTcyIiByPSIxMDAiLz4KICAgIDwvZz4KPC9zdmc+Cg==&#8221; quote_icon_color=&#8221;#000000&#8243; quote_icon_background_color=&#8221;#FFFFFF&#8221; font_icon=&#8221;&#xe092;||divi||400&#8243; portrait_width=&#8221;0px&#8221; portrait_height=&#8221;0px&#8221; disabled_on=&#8221;off|off|off&#8221; _builder_version=&#8221;4.27.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;||||false|false&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;]\n<p>Qui puoi scaricare la configurazione modbus all&#8217;interno di EVE Manager di alcune delle funzioni del dispositivo per il controllo di luci RGB <b>ASTRALPOOL Lumiplus<\/b>.<\/p>\n<p><strong><a href=\"https:\/\/support.ilevia.com\/wp-content\/uploads\/2024\/10\/ASTRALPOOL_lumiplus_It.zip\">Scarica il progetto qui!<\/a><\/strong>[\/et_pb_testimonial][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; inner_shadow=&#8221;on&#8221; _builder_version=&#8221;4.19.1&#8243; background_color=&#8221;#fafafa&#8221; parallax=&#8221;on&#8221; min_height=&#8221;280px&#8221; custom_margin=&#8221;30px||||false|false&#8221; locked=&#8221;off&#8221; collapsed=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row module_class=&#8221; et_pb_row_fullwidth&#8221; _builder_version=&#8221;4.16&#8243; width=&#8221;91%&#8221; width_tablet=&#8221;80%&#8221; width_phone=&#8221;&#8221; width_last_edited=&#8221;on|phone&#8221; max_width=&#8221;90%&#8221; max_width_tablet=&#8221;80%&#8221; max_width_phone=&#8221;&#8221; max_width_last_edited=&#8221;on|desktop&#8221; custom_padding=&#8221;30px|0px|22.8594px|0px|false|false&#8221; make_fullwidth=&#8221;on&#8221; collapsed=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; custom_padding=&#8221;|||&#8221; global_colors_info=&#8221;{}&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_text _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]\n<h1 style=\"text-align: center;\">Hai bisogno di aiuto? Il nostro servizio clienti \u00e8 qui per te.<\/h1>\n[\/et_pb_text][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; width=&#8221;100%&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.16&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_button button_url=&#8221;https:\/\/support.ilevia.com\/support-request\/&#8221; button_text=&#8221;Chiedi aiuto&#8221; button_alignment=&#8221;center&#8221; _builder_version=&#8221;4.19.1&#8243; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#1e84f4&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_width=&#8221;2px&#8221; button_border_color=&#8221;#1e84f4&#8243; button_font=&#8221;||||||||&#8221; button_use_icon=&#8221;off&#8221; custom_margin=&#8221;|0px|||false|false&#8221; custom_margin_tablet=&#8221;&#8221; custom_margin_phone=&#8221;|0px|||false|false&#8221; custom_margin_last_edited=&#8221;on|phone&#8221; box_shadow_style=&#8221;preset2&#8243; box_shadow_spread=&#8221;-80px&#8221; global_colors_info=&#8221;{}&#8221; box_shadow_spread__hover=&#8221;0px&#8221; box_shadow_spread__hover_enabled=&#8221;on&#8221;][\/et_pb_button][et_pb_button button_url=&#8221;https:\/\/support.ilevia.com\/support-request\/&#8221; button_text=&#8221;Dai un suggerimento&#8221; button_alignment=&#8221;center&#8221; _builder_version=&#8221;4.19.1&#8243; custom_button=&#8221;on&#8221; button_text_size=&#8221;20px&#8221; button_text_color=&#8221;#1e84f4&#8243; button_bg_color=&#8221;#FFFFFF&#8221; button_border_width=&#8221;2px&#8221; button_border_color=&#8221;#1e84f4&#8243; button_use_icon=&#8221;off&#8221; custom_margin=&#8221;|||0px|false|false&#8221; custom_margin_tablet=&#8221;&#8221; custom_margin_phone=&#8221;|||0px|false|false&#8221; custom_margin_last_edited=&#8221;on|phone&#8221; custom_padding=&#8221;|||25px|false|false&#8221; box_shadow_style=&#8221;preset2&#8243; box_shadow_spread=&#8221;-80px&#8221; locked=&#8221;off&#8221; global_colors_info=&#8221;{}&#8221; box_shadow_spread__hover=&#8221;0px&#8221; box_shadow_spread__hover_enabled=&#8221;on&#8221;][\/et_pb_button][\/et_pb_column][\/et_pb_row][\/et_pb_section]\n","protected":false},"excerpt":{"rendered":"<p>MODBUS-RTU &amp;\u00a0MODBUS-TCP Parametri dei GatewayMODBUS RTU\/ASCII PROPRIET\u00c0 DEL GATEWAY Seleziona dispositivo: L&#8217;opzione porta A sul gateway all&#8217;interno delle configurazioni del gateway indica la porta di sinistra presente nel server X1 fisico, la porta B quella a destra; Baud rate: Imposta il Baudrate come specificato nella documentazione del dispositivo; Bits: Imposta i Bit rispettivamente a come [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false,"footnotes":""},"categories":[1,72,18,30],"tags":[],"class_list":["post-10180","post","type-post","status-publish","format-standard","hentry","category-all","category-archivi","category-configuration-software-en","category-software-configurazione"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Modbus-gateway Ilevia Support |<\/title>\n<meta name=\"description\" content=\"Guida completa su come impostare il gateway Modbus RTU e Modbus TCP all&#039;interno del software di automazione e configurazione EVE Manager.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Filippo Amabilia\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"19 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/\"},\"author\":{\"name\":\"Filippo Amabilia\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#\\\/schema\\\/person\\\/08a8d13dee0bc9f160da55efe97b7959\"},\"headline\":\"Modbus-gateway\",\"datePublished\":\"2020-06-17T15:42:41+00:00\",\"dateModified\":\"2024-11-08T10:53:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/\"},\"wordCount\":3763,\"publisher\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#organization\"},\"articleSection\":[\"All Archives\",\"Archivi\",\"Configuration Software\",\"Software Configurazione\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/\",\"url\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/\",\"name\":\"Modbus-gateway Ilevia Support |\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#website\"},\"datePublished\":\"2020-06-17T15:42:41+00:00\",\"dateModified\":\"2024-11-08T10:53:28+00:00\",\"description\":\"Guida completa su come impostare il gateway Modbus RTU e Modbus TCP all'interno del software di automazione e configurazione EVE Manager.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/configuration-software-en\\\/modbus-gateway\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/support.ilevia.com\\\/it\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Software Configurazione\",\"item\":\"https:\\\/\\\/support.ilevia.com\\\/it\\\/archivi\\\/software-configurazione\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Modbus-gateway\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/\",\"name\":\"Ilevia Support\",\"description\":\"Assistance &amp; Technical Guides\",\"publisher\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#organization\",\"name\":\"Ilevia\",\"url\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/support.ilevia.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/ilevia.png\",\"contentUrl\":\"http:\\\/\\\/support.ilevia.com\\\/wp-content\\\/uploads\\\/2018\\\/12\\\/ilevia.png\",\"width\":500,\"height\":500,\"caption\":\"Ilevia\"},\"image\":{\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ileviaofficial\\\/\",\"https:\\\/\\\/www.instagram.com\\\/ilevia_official\\\/\",\"https:\\\/\\\/it.linkedin.com\\\/company\\\/ilevia\\\/\",\"https:\\\/\\\/www.youtube.com\\\/ilevia\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/support.ilevia.com\\\/en\\\/#\\\/schema\\\/person\\\/08a8d13dee0bc9f160da55efe97b7959\",\"name\":\"Filippo Amabilia\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g\",\"caption\":\"Filippo Amabilia\"},\"url\":\"https:\\\/\\\/support.ilevia.com\\\/it\\\/author\\\/filippo-amabilia\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Modbus-gateway Ilevia Support |","description":"Guida completa su come impostare il gateway Modbus RTU e Modbus TCP all'interno del software di automazione e configurazione EVE Manager.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/","twitter_misc":{"Scritto da":"Filippo Amabilia","Tempo di lettura stimato":"19 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/#article","isPartOf":{"@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/"},"author":{"name":"Filippo Amabilia","@id":"https:\/\/support.ilevia.com\/en\/#\/schema\/person\/08a8d13dee0bc9f160da55efe97b7959"},"headline":"Modbus-gateway","datePublished":"2020-06-17T15:42:41+00:00","dateModified":"2024-11-08T10:53:28+00:00","mainEntityOfPage":{"@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/"},"wordCount":3763,"publisher":{"@id":"https:\/\/support.ilevia.com\/en\/#organization"},"articleSection":["All Archives","Archivi","Configuration Software","Software Configurazione"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/","url":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/","name":"Modbus-gateway Ilevia Support |","isPartOf":{"@id":"https:\/\/support.ilevia.com\/en\/#website"},"datePublished":"2020-06-17T15:42:41+00:00","dateModified":"2024-11-08T10:53:28+00:00","description":"Guida completa su come impostare il gateway Modbus RTU e Modbus TCP all'interno del software di automazione e configurazione EVE Manager.","breadcrumb":{"@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/support.ilevia.com\/en\/configuration-software-en\/modbus-gateway\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/support.ilevia.com\/it\/"},{"@type":"ListItem","position":2,"name":"Software Configurazione","item":"https:\/\/support.ilevia.com\/it\/archivi\/software-configurazione\/"},{"@type":"ListItem","position":3,"name":"Modbus-gateway"}]},{"@type":"WebSite","@id":"https:\/\/support.ilevia.com\/en\/#website","url":"https:\/\/support.ilevia.com\/en\/","name":"Ilevia Support","description":"Assistance &amp; Technical Guides","publisher":{"@id":"https:\/\/support.ilevia.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/support.ilevia.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/support.ilevia.com\/en\/#organization","name":"Ilevia","url":"https:\/\/support.ilevia.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/support.ilevia.com\/en\/#\/schema\/logo\/image\/","url":"http:\/\/support.ilevia.com\/wp-content\/uploads\/2018\/12\/ilevia.png","contentUrl":"http:\/\/support.ilevia.com\/wp-content\/uploads\/2018\/12\/ilevia.png","width":500,"height":500,"caption":"Ilevia"},"image":{"@id":"https:\/\/support.ilevia.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ileviaofficial\/","https:\/\/www.instagram.com\/ilevia_official\/","https:\/\/it.linkedin.com\/company\/ilevia\/","https:\/\/www.youtube.com\/ilevia\/"]},{"@type":"Person","@id":"https:\/\/support.ilevia.com\/en\/#\/schema\/person\/08a8d13dee0bc9f160da55efe97b7959","name":"Filippo Amabilia","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0e396093874891309dc46571e6eec478bc2a5080be4f76a70e1ca9deb9f99eec?s=96&d=mm&r=g","caption":"Filippo Amabilia"},"url":"https:\/\/support.ilevia.com\/it\/author\/filippo-amabilia\/"}]}},"_links":{"self":[{"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/posts\/10180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/comments?post=10180"}],"version-history":[{"count":158,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/posts\/10180\/revisions"}],"predecessor-version":[{"id":75928,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/posts\/10180\/revisions\/75928"}],"wp:attachment":[{"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/media?parent=10180"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/categories?post=10180"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/support.ilevia.com\/it\/wp-json\/wp\/v2\/tags?post=10180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}